Whatman™ Anotop™ 10 Sterile Anopore Membrane Syringe Filter, 0.02 µm, 10 mm dia Membrane

Syringe Filter, Anotop™ 10, 0.02 µm Pore Size, Up to 10 ml, 15.4 x 18.5 mm, 10 mm dia Membrane, Proprietary Alumina Based Anopore Membrane, Sterile, Polypropylene Housing Material, Capillary Pore Structure with Narrow Pore-size Distribution

  • Manufacturer Part No: 6809-1112
  • SECO Part No: 12-4455-03
  • Sold As:
  • Availability: loading

Whatman Anotop sterile syringe filters from GE contain an inorganic Anopore membrane. The low protein binding exhibited by this sterile membrane filter make it well suited for biological filtration. Anotop™ syringe filters are a universal solution for numerous filtration applications. They can be used with most organic solvents and aqueous materials and are suitable for sample volumes up to 100 ml. The distinctive hexagonal housing is manufactured from pigment-free polypropylene to eliminate sample contamination. Anotop syringe filters contain the proprietary alumina based Anopore™ membrane and are supplied in three pore sizes. Glass microfiber Prefilter versions are available for difficult-to-filter samples.

Capacity : Up to 10 ml
Dimension : 15.4 x 18.5 mm
Membrane Diameter : 10 mm
Membrane Material : Proprietary Alumina Based Anopore Membrane
Housing Material : Polypropylene
Inlet Connector : Female Luer Lock
Outlet Connector : Male luer
Filtration Area : 0.78 cm2
Maximum Pressure : 6.9 bar (100 psi)
Sterility : Sterile
Protein Adsorption : Low
Shape : Hexagonal
Pore Size : 0.02 µm
Membrane Thickness : 60 µm
Membrane : Hydrophilic
Type : Anotop™ 10
  • Sterile syringe filters for critical applications
  • Aluminum-based inorganic Anotop syringe filters in three pore sizes
  • Compatible with most organic solvents and aqueous samples
  • Low hold-up volume (<20 µl for Anotop 10) for maximum sample recovery
  • Made without wetting agents or adhesives for low risk of sample contamination
  • Capillary pore structure supports highly consistent filtration results
  • Inorganic membrane
  • Sterile formats are available for critical applications
  • Cold sterilization of growth media
  • Phage and virus filtration
  • Removal of high molecular weight proteins or polymers
  • Liposome extrusion
  • Filtration of solvents for spectro analysis and analytical sample preparation