Dissolved Oxygen Module, 4.7 L x 1.2 W x 3.8" H, 0.5 lb Weight, 5 to 85 % & Non-condensing Relative Humidity, IP-54 IP Rating, 5 to 45°C Operating Temperature, -5 to +105°C Temperature Range, 0.1°C Temperature Resolution
Add dissolved oxygen and temperature measurement capabilities to your Thermo Scientific™ Orion™ Versa Star meter using the Thermo Scientific™ Orion™ Versa Star dissolved oxygen/RDO measurement module. Each Orion™ Versa Star meter has four channels that can be customized with interchangeable measurement modules. The Orion™ Versa Star RDO/DO module offers the flexibility to use Orion™ RDO optical or polarographic probes with automatic sensor recognition and calibration using water-saturated air, air-saturated water, custom value using Winkler titration and zero point options.
Length | : | 4.7" |
Height | : | 3.8" |
Width | : | 1.2" |
Accuracy (Barometer) | : | ±6 mm Mercury |
Accuracy (Polarographic DO) | : | ±0.2 mg/L or ±2% of Reading, Whichever is Greater |
Accuracy (RDO) | : | ±0.1 mg/L upto 8 mg/L, ±0.2 mg/L from 8 to 20 mg/L, ±10% of Reading upto 50 mg/L |
Accuracy (Temperature) | : | ±0.1°C |
Alarm Output | : | Set Point Alarm, High/Low Limit Alarm, Calibration Due Alarm |
Barometric Pressure Correction | : | 400 to 850 mm Mercury, Automatic Using Built-in Barometer or Manual Entry |
Calibration Modes | : | Water-saturated Air, Air-saturated Water, Manual (Winkler titration), Zero Point |
Includes | : | Versa Star RDO/DO Module and Printed Quick Start Guide |
Input | : | 9 pin MiniDIN (RDO Optical or Polarographic DO Sensor with Built-in Temperature) |
IP Rating | : | IP54 |
Measurement Mode | : | Dissolved Oxygen as % Saturation or mg/L with Temperature and Barometric Pressure |
Method | : | 10 per Channel with Password Protection |
Model | : | Orion Versa Star RDO Optical/Dissolved Oxygen/Temperature Measurement Module |
Operating Temperature | : | 5 to 45°C (Ambient) |
Percent Saturation Range (Polarographic DO) | : | 0 to 600% Saturation |
Percent Saturation Range (RDO) | : | 0 to 500% Saturation |
Percent Saturation Relative Accuracy (Polarographic DO) | : | ±2% Saturation |
Percent Saturation Relative Accuracy (RDO) | : | ±2% Saturation = 200% Saturation, ±10% Saturation > 200% Saturation |
Percent Saturation Resolution (Polarographic DO) | : | 0.1, 1% Saturation |
Percent Saturation Resolution (RDO) | : | 0.1, 1% Saturation |
Pressure Range | : | 400 to 850 mm Mercury |
Pressure Resolution | : | 0.1 mm Mercury |
Probe Type | : | RDO Optical Dissolved Oxygen Probe, Polarographic Dissolved Oxygen Probe |
Range (Polarographic DO) | : | 0 to 90 mg/L |
Range (RDO) | : | 0 to 50 mg/L |
Relative Humidity Range | : | 5 to 85%, Non-condensing |
Resolution (Polarographic DO) | : | 0.01, 0.1 mg/L; 0.1, 1 % Saturation |
Resolution (RDO) | : | 0.01, 0.1 mg/L; 0.1, 1 % Saturation |
Resolution (Temperature) | : | 0.1°C |
Salinity Factor | : | 0 to 45 ppt |
Sensor Type | : | Polarographic or RDO (optical) DO Probe |
Stability | : | Selectable Fast, Medium, Slow or Smart Stability Setting; Selectable off or Automatic Smart Averaging Setting |
Temperature Probe Calibration | : | 1 Point Temperature Offset Calibration |
Temperature Range | : | −5 to 105°C |
Temperature Selection | : | Automatic with ATC Temperature Probe |
Warranty | : | 3 Years Meter Replacement |
Weight | : | 0.5 lb |